<LOGO>
FM Transmitter Measurement Report
Created: 2024-01-22 18-26-47
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
89.90 MHz 5/5, 80 dBuV FREQ 3
Pilot RDS Phase Difference
6.7 kHz 3.2 kHz 2 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
10 kHz 71 kHz 19059 0,0735
Modulation Power
Limit Measuring Tolerance
9,0 dBr 1,0 dBr
MIN AVE MAX % above 10,0 dBr
6,6 dBr 7,79 dBr 8,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" FREQ 3 " F536 10 (Pop M) 1 0 1 3 18:26, 22.01.2024
RT
"Teddy Swims -> Lose Control "
AF EON
89.9, 99.0 MHz -
FM Scope Station: 89.90 MHz, signal: 5/5 (80 dBuV) Max at: 71 kHz MIN: 10 kHz % above 75 kHz: 0,0735 Acquired: 2024/01/22 18:25:43 Total samples: 19059 Equivalent time: 0:15:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 2000 4000 6000
FM Scope MAX: 8,6 dBr MIN: 6,6 dBr AVE: 7,79 dBr % above 10,0 dBr: 0,0 Last value: 7,4 dBr (2024/01/22 18:25:42) Station: 89.90 MHz, signal: 5/5 (80 dBuV) 18:12 18:14 18:16 18:18 18:20 18:22 18:24 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality